Skip to content
Industrial transformer and electrical substation
Altek Green / Power Systems

Power your operation.
Renew its potential.

From complex network studies to switchgear renewal and on-site fabrication, we bring life to your engineering assets.

Explore our expertise
STUDY & DESIGNINSTALL & COMMISSIONMAINTAIN & MODERNIZE
Power systems engineering

Reliable substations.
Resilient operations.

POWER IN MOTIONExplore the network ↗
From substation to productive industryAn animated illustration connects grid supply, a transformer and switchgear to an industrial facility. Select the equipment to explore commissioning, protection and switchgear services.Substation commissioningGRID SUPPLYTransformer commissioningTRANSFORMSwitchgear maintenancePROTECTProtection testing for reliable operationsKEEP INDUSTRY MOVING

Practical MV and HV substation engineering for mining, industry and utilities across Johannesburg and South Africa.

Altek Green combines technical expertise with hands-on field experience to design, commission and maintain protection and control systems. From new substations to legacy equipment retrofits, we help clients strengthen reliability, manage downtime and extend asset life.

Our work spans primary and secondary plant, indoor and outdoor switchgear, and air-, oil- and gas-insulated systems. We use calibrated, certified test equipment and disciplined working practices to meet project requirements and applicable local and international standards.

Through clear reporting, professional workmanship and continuous improvement, we build lasting partnerships around the needs of your operation.

ENGINEERED AROUND YOUR ASSETSFrom insight to implementation ↗
Our power systems offering

Expertise at every
stage of your network.

Explore eight areas of engineering support, from understanding system performance to extending the life of existing equipment.

Engineers reviewing electrical network studies at a workstation01Network studies
Studies & analysis

Load Flow Studies on Complex Electrical Networks

Understand how power moves through your network. Assess operating conditions and plan around the demands of your electrical assets.

Discuss this service ↗
OMICRON CMC 356 protection relay test set and commissioning panel02Protection & reliability
Protection & earthing

Electrical Protection Grading, Testing, Commissioning, and Maintenance

Bring protection grading, testing, commissioning and ongoing maintenance together across the life of your electrical systems.

Discuss this service ↗
Megger DET4TC2 earth tester and test leads beside a copper earthing bar03Earthing systems
Protection & earthing

Earthing System Design, Installation, Testing, and Audits

From design and installation to testing and audits, address the earthing requirements of your site as a connected engineering scope.

Discuss this service ↗
Fluke 1777 power quality analyzer with flexible current probes04Power quality
Studies & analysis

Power Factor and Harmonic Studies

Investigate power factor and harmonic performance to inform your next power quality improvement or equipment upgrade.

Discuss this service ↗
Industrial power factor correction cabinet with capacitors and reactors05Power factor correction
Equipment & upgrades

Power Factor Correction Equipment Design, Installation, and Maintenance

Take power factor correction equipment from design through installation and maintenance, with a focus on your operating requirements.

Discuss this service ↗
Modern medium voltage switchgear lineup06Switchgear renewal
Equipment & upgrades

Low and Medium Voltage Switchgear Retrofits, Modernization, and Modification

Renew existing switchgear through retrofits, modernization and modification, aligned with the needs of your operation.

Discuss this service ↗
Precision formed copper busbars beside a hydraulic bending press07Fabrication & fitment
Equipment & upgrades

Bus Bar Manufacture and On-site Bus Bar Bending, Pressing, and Fitment

Combine bus bar manufacture with on-site bending, pressing and fitment for your electrical installation or upgrade.

Discuss this service ↗
Flameproof electrical junction boxes in an industrial process facility08Specialist environments
Hazardous areas

Hazardous Areas Design and Installation for Explosive Atmospheres (Gases and Liquids)

Discuss electrical design and installation requirements for hazardous areas involving gases and liquids.

Discuss this service ↗
Testing, maintenance & commissioning

Specialist support.
From relay to substation.

Explore the scope behind our services, from planned maintenance to commissioning new or renewed assets.

OMICRON CMC 356 test set connected to a protection relay panel
Protection & reliability
Protection & reliability

Protection Relay Testing

Verify that protection operates as intended. We test, configure and maintain relays for new installations and existing MV and HV substations, helping protect people, equipment and network stability.

Testing, configuration & reporting
  • Secondary current injection testing to verify protection relay performance against the required settings and design.
  • Maintenance testing for generation, transmission and distribution systems.
  • Multi-OEM relay programming and configuration, including ABB, Schneider Electric, MiCOM, VAMP and General Electric.
  • Clear test reports with findings and practical recommendations for system improvement.
OEM knowledge & operational support

We support protection platforms from ABB, SEL, Schneider Electric, GE, Siemens and VAMP, including MiCOM relays.

Testing is planned around your outage requirements to minimise disruption. Our team follows site safety procedures, uses calibrated test equipment and provides clear communication to support compliance, maintenance planning and reliable operation.

Discuss relay testing
Indoor medium voltage switchgear lineup
Preventative maintenance
Preventative maintenance

Switchgear Maintenance

Keep mechanisms, contacts and control circuits ready to operate when required. Our preventative maintenance services help reduce the risk of mal-operation, equipment failure and unplanned production outages.

Preventative maintenance scope
  • Inspect circuit breaker condition and check for visible defects.
  • Clean and lubricate circuit breaker mechanisms.
  • Measure contact resistance at the primary contacts.
  • Perform circuit breaker speed and timing tests, and high-potential (hipot) tests.
  • Carry out secondary current injection testing on protection relays and primary injection testing on current transformers.
  • Function-test DC control and trip circuits, including circuit breaker tripping.
  • Inspect ammeters and voltmeters for visible damage.
  • Open, inspect and clean busbar chambers; inspect connections on all three phases.
Switchgear types & supported ranges

We service indoor metalclad switchgear at 3.3 kV, 6.6 kV, 11 kV, 22 kV and 33 kV, including oil-insulated, air-insulated, SF6 gas-insulated and vacuum circuit breaker equipment.

  • ABB: UniGear panels, SafePlus and SafeRing ring main units, and former Reyrolle panels with LMT and LMR circuit breakers.
  • Actom: SBV and SVBE switchgear ranges.
Plan switchgear maintenance
Outdoor medium voltage capacitor bank at an industrial substation
Power factor correction
Power factor correction

Capacitor Bank Maintenance

Maintain dependable power factor correction with servicing for 3.3 kV, 6.6 kV, 11 kV, 22 kV and 33 kV capacitor banks used by mines, utilities and industrial operations.

Capacitor bank service scope
  • Check and test capacitor units and assess bank balance.
  • Inspect and test the capacitor bank circuit breaker.
  • Test protection relays on the capacitor control panel.
  • Balance capacitor banks and document the service findings.
  • Issue concise, detailed test reports to support maintenance decisions.
Discuss capacitor bank servicing
Withdrawn circuit breaker with timing analyzer and contact resistance testing equipment
Equipment & technical support
Equipment & technical support

Circuit Breaker Test Equipment Hire

Access specialist circuit breaker test equipment with a technician to operate it. Support your electrical project, planned shutdown or maintenance programme with the right testing resources.

Equipment available with an operator
  • Circuit breaker speed and timing testers for breaker operating assessments.
  • Contact resistance testers for primary contact resistance measurements.
  • A technician to operate the test equipment as part of the hire service.
Enquire about equipment hire
Industrial transformer and outdoor substation equipment
Cold & hot commissioning
Cold & hot commissioning

Substation Commissioning

Bring new substation equipment into service with precise testing of installation and performance. We carry out cold and hot commissioning for utilities, mines and industry, including recommissioning after major repairs or retrofits.

Primary & secondary plant
  • Protection relays and protection panels.
  • Circuit breakers and disconnectors.
  • Voltage transformers (VTs) and current transformers (CTs).
  • DC supplies, including batteries and battery chargers.
  • AC supplies and distribution boards.
  • Primary plant interfaces to protection and control panels.
  • Capacitor banks and substation earthing.
Protection schemes commissioned
  • Overcurrent and over-/undervoltage protection.
  • Frequency protection.
  • Transformer protection.
  • Distance and line differential protection.
  • Busbar and capacitor bank protection.
  • Motor and generator protection.
Scope substation commissioning
Bringing life to your engineering assets

Your next upgrade.
Starts with a conversation.

Tell us about your network, your equipment and the challenge you need to solve.

Talk to Altek Green
Alfred · Altek Green AI assistant

Welcome! Ask me about our engineering services, drives or parts.